Firestop Technical Resources

View the Facility Safety Technical Library
3M™ brings firestop technical information closer to our valued customers. Here you'll find technological information for 3M Fire Protection Products and Solutions.

Firestop Product Specifications

3M™ Fire Protection Products are currently grouped into 4 main categories:

Architectural Specification of 3M Fire Protection Products for Through Penetrations (RTF, 367KB)

Architectural Specification of 3M Fire Protection Products for Construction Joints (RTF, 135KB)

Architectural Specification of 3M Fire Protection Products for Flexible Wrap Systems (RTF, 268KB)

Architectural Specification of 3M Fire Protection Products for General Firestopping (RTF, 428KB)

3M™ Fire Protection Product Specifications are available on ARCAT.com (website for Building Materials and Manufacturers Specifications for the Architectural and Spec Writing Communities)

Note, Arcat currently defaults to MasterFormat 1995, you can toggle to MasterFormat 2004 in the upper right areas of Arcat's landing page.

  • A specification is an explicit set of requirements to be satisfied by a material, product, or service. In the North American construction process, specifications are used as a set of "blueprints” to help govern materials, products and methods used in building construction. MasterFormat is recognized in both Canada and the United States as the guiding document for building specifications (MasterFormat is a product of the Construction Specifications Institute (CSI) and Construction Specifications Canada). MasterFormat 2004 is the most current version of this document. Within MasterFormat 2004, specifications are grouped in 50 Divisions which are further broken into subcategories called Sections.

    MasterFormat 2004 organizes similar work result, product, requirement and activities into a hierarchical format with "levels”. The broadest category (Level 1) is the Division. Within a division, there may be several Level 2 subcategories know as Sections. Each Division can have up to 4 levels, with each subsequent level providing more detail regarding the specification. Generally, level 4 numbers are not utilized, but when they are, an additional pair of digits is attached to the end, preceded by a "dot.”

    For example, firestopping is addressed in Section 07 84 00. Here, (07) denotes Level 1 (Division). The title of this Division is listed as "Thermal and Moisture Protection”. (84) denotes the Section "Firestopping”. This particular specification lists 3 Levels, with the 3rd Level (00), left open. Had the specification been 07 84 13, the Level 3 digits (13) would have further defined the information as pertaining specifically to "Penetration Firestopping".

    To learn more about MasterFormat 2004, including the transition from 1995 to 2004 specifications, click here.


  • CAD Drawings and BIM Files
  • Code Approvals and Certificates of Conformance
  • Technical Bulletins